case background:

a customer receives complaints and finds a type connector of its products is poor contact affecting the performance. the customer enlarges the sample and finds that the surface of the product has a white area which is different from the normal position.

 

test method:

ftir analysis

 

inspection standard:

gb/t 6040-2002, the general principles of the infrared spectrum analysis method

 

analysis summary:

1.abnormal product surface with white material was found through a stereoscopic microscope magnification, see below:

 

 

2.take pictures for the samples, determine the test position. since the sample is copper substrate, no infrared light absorption and the reflective light is good which can directly use microscopic infrared to do reflection test for the sample surface with accurate position, fast speed and good quality graph.

 

 

conclusion:

the infrared spectrum analysis, according to their molecular structure characteristics, combined with standard infrared spectrum shows that the organic principal component of the material is succinic acid. succinic acid is a kind of good surfactants and is the component of detergents, soaps and demulsifier.



  • contact us
  • mtt shenzhen

    tel: 400-850-4050

    fax: 0755-2782 1672

    email: marketing@mttlab.com

     

    mtt suzhou

    tel: 400-118-1002

    fax: 0512-6275 9537

    email: marketing@mttlab.com

     

    mtt shanghai

    tel: 400-118-1002

    email: marketing@mttlab.com

     

    mtt dongguan

    tel: 400-116-1002

    email:marketing@mttlab.com

shenzhen meixin testing technology co., ltd.

"));
网站地图