horizontal flammability test -j9九游会登录入口


horizontal flammability test

 

vertical flammability test the oxygen index test
glow wire test horizontal flammability test
needle-flame test flammability of interior materials

 

test standard:

ul94-2015, 4943.1-2011 gb, 2408-2008 gb/t, 5169.16-2008 gb/t, etc..

 

scope:

plastic, foam, film, textile, paint, rubber, etc., are not applicable to building materials.

 

sample size:

length 125±5mm, width 13±0.5mm, thickness 0.025~13mm

 

test pretreatment:

a set of 3 samples at23±2℃, 50±5%rh adjustment at least 48h

 

tested condition:

the flame height is 20±1mm, the ignition time is 30±1s, the flame source is tilted 45 degrees, and the sample holder is kept at 45 degrees with the horizontal plane.

 

hb criteria:

1)not have a burning rate exceeding 40mm per minute over a 75mm span for specimens having a thickness of 3.0~13mm, or

2)not have a burning rate exceeding 75mm per minute over a 75mm span for specimens having a thickness less than 3.0mm, or

3)cease to burn before the 100mm reference mark.

4)a material classified hb in the 3.0 0.2 mm thickness shall automatically be classed hb down to a 1.5 mm minimum thickness without additional testing.

 

test schematic diagram

 

case:

typical cases

reference standard:

fuel test for plastic materials for ul94-2015 equipment and appliances.

tested flow:take picture→mark on specimens at 25mm and 100mm→set parameters of instrument→start testing 

 

tested condition:

level of combustion flame height requirement is 20 ± 1mm, the ignition time is 

30±1s, flame source tilt 45 °, with the level of the sample holder maintained between 45 °.

sample size:127mm×13mm×4.4mm

 

hb criteria:

1)not have a burning rate exceeding 40mm per minute over a 75mm span for specimens having a thickness of 3.0~13mm, or

2)not have a burning rate exceeding 75mm per minute over a 75mm span for specimens having a thickness less than 3.0mm, or

3)cease to burn before the 100mm reference mark.

4)a material classified hb in the 3.0 0.2 mm thickness shall automatically be classed hb down to a 1.5 mm minimum thickness without additional testing.

 

test result:

 

test sample test result(mm/min)
--------- 1 30.1
2 32.5
3 28.7
maximum value 32.5

 

conclusion:the samples comply with ul94-2015 hb.



  • contact us
  • mtt shenzhen

    tel: 400-850-4050

    fax: 0755-2782 1672

    email: marketing@mttlab.com

     

    mtt suzhou

    tel: 400-118-1002

    fax: 0512-6275 9537

    email: marketing@mttlab.com

     

    mtt shanghai

    tel: 400-118-1002

    email: marketing@mttlab.com

     

    mtt dongguan

    tel: 400-116-1002

    email:marketing@mttlab.com

shenzhen meixin testing technology co., ltd.

"));
网站地图